POWER PLANTS & INDUSTRIAL ZONES
Resilient power for the infrastructure that powers everything.
ENCLOVE supports power stations, substations, process plants, and industrial zones with dependable UPS, DC, rectification, and automation-ready conversion systems.
+25 YEARS OPERATING UNITS IN HARSH CONDITIONS

Continuous operation, from generation to grid.
Our systems protect control rooms, switchgear, turbine auxiliaries, and mission-critical process equipment against disturbances, outages, and demanding operating conditions.
FROM GENERATION TO GRID
Power systems that protect the process behind the megawatts.
Generating assets and industrial zones rely on uninterrupted control power to coordinate protection, switching, auxiliaries, and process automation. ENCLOVE systems isolate these critical loads from supply events and provide the autonomy required for safe, orderly response.
THE CONTROL POWER PATH
Where control power sits in the chain.
The loads behind the megawatts.
UPS and DC systems support protection relays and control rooms; battery chargers maintain standby banks; inverters sustain AC auxiliaries; and tailored power conversion packages align with each site’s voltage, autonomy, and redundancy requirements.
| Load | What supports it |
|---|---|
| Control rooms | UPS and DC systems |
| Switchgear | DC systems |
| Turbine auxiliaries | Industrial UPS |
| Protection relays | UPS and DC systems |
| Standby battery banks | Battery chargers |
| AC auxiliaries | Inverters |

Systems specified for generating and industrial sites
Each product family below is sized to the load, duty, and site conditions it protects.

Industrial UPS
LEON-A Series
Industrial UPS for control rooms
- Power Range
- 10-500kVA
- DC Bus
- 110 - 384VDC

Industrial DC UPS
ESD Series
DC systems for protection and switchgear
- Voltage Range
- 24VDC-600VDC
- Current Range
- 10A to 2000A

Modular Rectifier
ETR Series (ETR1524)
Battery charging, 24 V standby banks
- Module Power
- 1500W
- Voltage Range
- 21VDC - 30VDC

Modular Rectifier
ETR Series (ETR3048)
Battery charging, 48 V standby banks
- Module Power
- 3000W
- Voltage Range
- 43VDC - 60VDC

Industrial Inverter
EVR Series
AC auxiliaries from the station DC bus
- Voltage Range
- 24VDC-600VDC
- Power Range
- 1kVA to 500kVA
Further reading
Industrial UPS Systems for Power Plants and Heavy Industry
A plant is not a datacenter, and specifying datacenter-shaped equipment for one is the usual mistake. What genuinely differs — the environment, the mixed AC and DC load, the electrical context, galvanic isolation and a service life measured in decades — and how to specify around it.
Galvanic Isolation in UPS Systems, and Why Industrial Sites Need It
Galvanic isolation puts a transformer winding between a UPS input and its output so that no conductive path remains between them. Here is what that buys on an industrial site, why many modern UPS designs deliberately leave it out, and how to confirm which paths in a machine are actually isolated.
UPS Battery Maintenance and Testing
The battery is the part of a UPS most likely to be the reason it fails to hold the load, and the only part that degrades whether or not anything goes wrong. What a maintenance regime should inspect, measure and test — and why a self-test is not a capacity test.
UPS Redundancy Explained: N+1, 2N and 2N+1
N+1, 2N and 2N+1 are notation, not ratings. What each one actually buys, why being maintainable and being fault-tolerant are different properties, and where the single path survives inside a design everyone calls redundant.
Power plant and industrial zone questions
Which loads do ENCLOVE systems protect in a power plant or substation?
Why do generating assets need uninterrupted control power?
How is a system matched to a particular site?
What keeps a station's standby battery bank ready?
Other sectors we power
NEED SOMETHING SPECIFIC
Can't Find Exactly WhatYou Are Looking For?
Our engineering team specialises in bespoke power solutions. Share your requirements and we'll design a system built precisely for your application.