DATACENTERS & TELCO INFRASTRUCTURE
Always-on power for the world’s digital backbone.
ENCLOVE creates scalable, high-availability power systems for datacenters, telecom networks, and edge infrastructure where uptime, efficiency, and maintainability are essential.
MODULAR, HOT SWAP AND EASILY MAINTAINABLE UNITS

Scalable protection for every rack, room, and region.
With modular UPS architecture, intelligent monitoring, and flexible redundancy options, our solutions help teams protect demanding loads without compromising future growth.
SCALE
How far the modular platforms scale.

UPTIME BY DESIGN
A resilient power chain is the foundation of digital availability.
Datacenters demand more than backup power. They require predictable performance during maintenance, seamless support for growth, and visibility across every critical path. ENCLOVE modular solutions help operators protect today’s load while planning confidently for tomorrow’s capacity.
THE POWER CHAIN
Every stage between the grid and the rack.
- 01 Utility supply
- 02 Switchgear
- 03 UPS
- 04 Distribution
- 05 Rack
Critical power architecture for digital infrastructure.
Modular UPS platforms deliver scalable protection for IT and facility loads, while DC systems, rectifiers, and intelligent monitoring support telecom, edge, and network infrastructure with the control teams need to keep availability high.
Systems specified for digital infrastructure
Modular platforms for IT and facility loads, with DC systems and rectifiers for telecom, edge and network sites.

Modular UPS
CUMULUS POWER
Modular UPS for IT and facility loads
- Power Range
- 10kW-3.6MW
- Module per Frame
- 1 to 10 Module

Modular UPS
STRATUS POWER
Modular UPS at high power density
- Power Range
- 10kW-3.75MW
- Power Footprint
- 1MW per M²

Industrial DC UPS
ESD Series
DC systems for telecom and network loads
- Voltage Range
- 24VDC-600VDC
- Current Range
- 10A to 2000A

Modular Rectifier
ETR Series (ETR1524)
Rectifiers for 24 V DC plant
- Module Power
- 1500W
- Voltage Range
- 21VDC - 30VDC

Modular Rectifier
ETR Series (ETR3048)
Rectifiers for 48 V DC plant
- Module Power
- 3000W
- Voltage Range
- 43VDC - 60VDC
Further reading
The Datacenter Power Chain, From Grid to Rack
Every stage of a datacenter power chain fails in its own way, and only one of them can bridge a loss of supply with no interruption at all. A stage-by-stage walk from the utility transformer to the rack PDU, with the failure modes and the redundancy that answers each one.
Modular vs Monolithic UPS: What Scalability Buys
A modular architecture changes the capital profile, the repair time and the floor plan of a UPS installation — and leaves several single points of failure exactly where they were. How to tell the two apart before you order.
UPS Redundancy Explained: N+1, 2N and 2N+1
N+1, 2N and 2N+1 are notation, not ratings. What each one actually buys, why being maintainable and being fault-tolerant are different properties, and where the single path survives inside a design everyone calls redundant.
Datacenter power questions
How far do ENCLOVE modular UPS platforms scale?
What do datacenters need beyond backup power?
What supports telecom and edge sites?
Can capacity grow after the first installation?
Other sectors we power
NEED SOMETHING SPECIFIC
Can't Find Exactly WhatYou Are Looking For?
Our engineering team specialises in bespoke power solutions. Share your requirements and we'll design a system built precisely for your application.